The patented Coolsure ETS is a high efficiency split-type precision cooling system, ideally suited for telecom shelter sites such as BTS, BSC and Hub sites, as well as small server rooms.
The Coolsure ECS cooling system provides energy saving free cooling for BTS shelters, providing up to 90% energy savings compared to comfort air conditioners when used in cool/dry climates.
Coolsure Free Cooling Controls
Deployed free cooling systems which don't work as promised, or where vendor support is lacking? Coolsure's third generation free cooling controls are available for retrofit use with third party free cooling assemblies.
The Coolsure ECS free cooling system cooling system provides energy saving free cooling for BTS shelters, providing up to 90% energy savings compared to comfort air conditioners when used in cool/dry climates.
When deploying free cooling solutions in tropical climates, care needs to be taken not to introduce damaging hot/humid air into the shelter. Coolsure ECS free cooling system incorporates accurate psychrometric sensors which continuously monitor the temperature and humidity of the outside air and prevent damaging hot/humid air from being introduced into the shelter.
Key Features
Incorporates enthalpy (humidity) control to prevent excessive damaging humidity from being introduced into BTS shelter
Optional long-life washable waterproof membrane filter for best protection against contaminants such as salt spray, acid mist, etc, in problem areas
Speed controlled DC fan reduces power consumption
Can directly connect to Coolsure air conditioners via built in CoolBus to provide optimised integrated hybrid cooling system
Can control up to two external third party air conditioners via “failsafe” relay units – automatic changeover function and activation of standby air conditioner in case of failure of active unit
Emergency cooling during AC power failure
Positive pressurisation ensures no dirty air is drawn into shelter via gaps or other openings
No access needed to inside shelter for filter replacement/service
Comprehensive built in alarms can be mapped to four programmable relay outputs
Optional smoke detector shutdown input
Connects to optional Central Control Unit (CCU) to allow full adjustment and monitoring of operating parameters
Coolsure ECS free cooling system can provide the lowest Total Cost of Ownership (TCO) for Telecom operators when:
Used as the sole cooling solution in cool/dry climates
Combined with Coolsure high efficiency airconditioners in climates with both hot and cool periods (eg hot days/cool nights or hot summers/cool winters)
Combined with existing low efficiency air conditioners to provide a hybrid cooling solution for existing BTS shelter sites in mostly cool, but occasionally hot climates
Used with an elevated shelter indoor temperature and humidity in hot/humid climates, where energy cost savings outweigh the cost of increased equipment failure and battery and filter replacements.
Support for remote monitoring and control capability via Coolsure Sentinel remote monitoring system, or third party remote monitoring system (via Modbus adaptor).