High Energy Efficiency Cooling Solutions
Reliable & Cost Saving Cooling Systems

PrevNext
Coolsure UTS (3.6kW & 5.5kW)

Coolsure UTS (3.6kW & 5.5kW)

The patented Coolsure UTS is an energy
saving uninterruptible cooling system, ideally
suited for telecom shelter sites such as BTS,
BSC and Hub sites.

more
Coolsure ETS (5.5kW)

Coolsure ETS (5.5kW)

The patented Coolsure ETS is a high efficiency
split-type precision cooling system, ideally
suited for telecom shelter sites such as BTS,
BSC and Hub sites, as well as small server rooms.

Coolsure ECS free cooling system

Coolsure ECS (2800)

The Coolsure ECS cooling system provides energy
saving free cooling for BTS shelters, providing up to 90%
energy savings compared to comfort air conditioners when
used in cool/dry climates.

more
Coolsure Free Cooling Controls

Coolsure Free Cooling Controls

Deployed free cooling systems which don't work as promised,
or where vendor support is lacking? Coolsure's third
generation free cooling controls are available for retrofit
use with third party free cooling assemblies.

more

Coolsure ETS (5.5kW)

The patented Coolsure ETS is high efficiency split-type precision cooling system, ideally suited for telecom shelter sites such as BTS, BSC and Hub sites, as well as small server rooms.
Coolsure UTS air conditioners facilitate intelligent, modular redundant system configurations, providing expandability and high availability cooling with low running costs.
    The chart shows the impact of increasing temperature and humidity on the failure rate of the electronics and batteries.
    Coolsure UTS air conditioners provide active moisture control, removing any excess moisture which may be present in the controlled space, while ensuring air is not overdried to prevent electrostatic discharge (ESD).
Substantial energy savings for new and existing sites

Equipped with innovative features and high performance components, Coolsure UTS air conditioners use less than half the energy of typical comfort and precision airconditioning systems, in a package that can be deployed as a direct replacement for standard split units.

Power and Energy Metering

If you can’t measure it, you can't manage it. Standard air conditioners deployed at BTS sites typically use 30 to 50% of the total site load, but provide no built in energy measurements, hiding the true cost of operating them. Coolsure ETS air conditioners are equipped with accurate built-in energy metering which records total energy consumption (since installation and since reset) as well as instantaneous power measurement. The built in energy metering allows users to quantify and report the ongoing impact of energy saving initiatives and facilitates optimisation of network-wide energy consumption.

High availability, modular redundant cooling

The fans and compressors are operated at variable speeds eliminating the stresses of on/off regulation and extending the life of all major components. Coolsure’s patented control technology features dynamic load sharing and a sophisticated maintenance alarm system, as well as supporting N+1 redundant configurations to prevent system failure caused by unit faults.

Reduced carbon footprint without compromising network reliability

Unlike alternative cooling solutions, such as free venting and heat-exchangers, Coolsure UTS air conditioners allow operators to substantially reduce their carbon footprint without compromising on the reliability and life of the critical telecom equipment and batteries.

Support for remote monitoring and control capability via Coolsure Sentinel remote monitoring system, or third party remote monitoring system (via Modbus adaptor).